User manual
Table Of Contents
- 1 General information
- 2 Quick guide
- 3 Overview
- 4 Installation of the base system
- 5 Initial commissioning of the base system
- 6 Installation and initial commissioning of optional components
- 6.1 Commissioning the SD card (MPPT 6000-M only)
- 6.2 AUX 1,2,3 relay output connection (MPPT 6000-M only)
- 6.3 AUX IO remote control input connection (MPPT 6000-M only)
- 6.4 PA TS-S external temperature sensor connection
- 6.5 StecaLink slave connection
- 6.6 StecaLink master connection (MPPT 6000-M only)
- 6.7 UART/RS-232 interface connection (MPPT 6000-M only)
- 6.8 Redundancy function (MPPT 6000-S only)
- 6.9 Install cable strain relief
- 7 Display (layout, function, operation)
- 8 System functions
- 8.1 Protection functions
- 8.2 Battery type setting
- 8.3 Current limit system setting (MPPT 6000-M only)
- 8.4 Current limit device setting
- 8.5 Lead-acid battery system functions
- 8.5.1 Equalisation cycle mode
- 8.5.2 Battery control mode (MPPT 6000-M only)
- 8.5.3 Battery capacity test (MPPT 6000-M only)
- 8.5.4 Battery type
- 8.5.5 Battery capacity
- 8.5.6 Current limit system (MPPT 6000-M only)
- 8.5.7 Current limit device
- 8.5.8 Charge voltages
- 8.5.9 IUIA charge mode (MPPT 6000-M only)
- 8.5.10 Start boost charge
- 8.5.11 Battery temperature sensor
- 8.5.12 Cable compensation
- 8.5.13 PV string connection
- 8.5.14 Expert menu
- 8.6 Li-Ion battery system functions (MPPT 6000-M only)
- 8.7 NiCd battery system functions (MPPT 6000-M only)
- 8.8 StecaLink bus
- 8.9 Internal data logger
- 8.10 Clear log data
- 8.11 Clear event log
- 8.12 Factory settings
- 8.13 UART/RS-232 interface (MPPT 6000-M only)
- 8.14 Acoustic alarm
- 8.15 SD card (MPPT 6000-M only)
- 9 Control functions via AUX 1/2/3 (MPPT 6000-M only)
- 10 Troubleshooting
- 11 Maintenance, dismounting and disposal
- 12 Technical data
- 13 Guarantee conditions, exclusion of liability, contacts, notes

3.4 Menu structure
For the sake of clarity, only the Ñ
and SET operating buttons are illustrated.
Set Set
Set Set
A)
Set
Set Set Set
Set
Set Set
B)
Set
Set Set Set
C)
Set
Set Set Set
D)
Set Set Set
E)
Set Set Set
F)
Set
Set Set
Set
Set
Set
Set Set
Set Set Set
Set
Set
Set
Set
Set
Set Set
Set
Set
Set
Set
Set
*1) MPPT 6000-M only
*3) SOC Control mode only
*2) MPPT 6000-S only
Status display
Basic position
Main window
Charge current MPPT
Battery voltage
Voltage ext. bat. sense
SOC
*1, *3
Result of capacity test
*1
PV 1 voltage
PV 2 voltage
PV power total
PV 1 power
PV 2 power
Operating hours
Total charge/discharge
current of battery
*1
Total discharge current of
battery
*1
Total charge/discharge
power of battery
*1
Total charge current of
battery
*1
Device On/Off
Settings AUX 1/2/3
*1
Internal data logger
SD card
*1
System settings
Battery settings
Event log
Information
Energy input
Main menu
Device On/Off
[ ] On
[ ] Off
[ ] Remote *1 / [ ] Redundancy *2
Energy output
*1
Min. battery voltage
Max. battery voltage
Max. charge current
Max. PV 1 voltage
Max. PV 2 voltage
Last 18 hours
Day
Month
Year
Total
Configuration
*1
Graphic
List for last 30 days
Ah
List for last 12 months
Ah
Total yield info
Ah
List for last 20 years
Ah
Energy input members
[ ] MPPT power unit
[ ] …..
Graphic
Graphic
Last 18 hours
Day
Month
Year
Total
Configuration
*1
Graphic
List for last 30 days
Ah
List for last 12 months
Ah
Total yield info
Ah
List for last 20 years
Ah
Energy output members
[ ] MPPT power unit
[ ] …..
Graphic
Graphic
List for last 30 days
V
List for last 30 days
V
List for last 30 days
A
List for last 30 days
V
List for last 30 days
V
Power information from
StecaLink slave
participants
*1
756.404 | Z01 | 16.06