User manual
Table Of Contents
- 1 General information
- 2 Quick guide
- 3 Overview
- 4 Installation of the base system
- 5 Initial commissioning of the base system
- 6 Installation and initial commissioning of optional components
- 6.1 Commissioning the SD card (MPPT 6000-M only)
- 6.2 AUX 1,2,3 relay output connection (MPPT 6000-M only)
- 6.3 AUX IO remote control input connection (MPPT 6000-M only)
- 6.4 PA TS-S external temperature sensor connection
- 6.5 StecaLink slave connection
- 6.6 StecaLink master connection (MPPT 6000-M only)
- 6.7 UART/RS-232 interface connection (MPPT 6000-M only)
- 6.8 Redundancy function (MPPT 6000-S only)
- 6.9 Install cable strain relief
- 7 Display (layout, function, operation)
- 8 System functions
- 8.1 Protection functions
- 8.2 Battery type setting
- 8.3 Current limit system setting (MPPT 6000-M only)
- 8.4 Current limit device setting
- 8.5 Lead-acid battery system functions
- 8.5.1 Equalisation cycle mode
- 8.5.2 Battery control mode (MPPT 6000-M only)
- 8.5.3 Battery capacity test (MPPT 6000-M only)
- 8.5.4 Battery type
- 8.5.5 Battery capacity
- 8.5.6 Current limit system (MPPT 6000-M only)
- 8.5.7 Current limit device
- 8.5.8 Charge voltages
- 8.5.9 IUIA charge mode (MPPT 6000-M only)
- 8.5.10 Start boost charge
- 8.5.11 Battery temperature sensor
- 8.5.12 Cable compensation
- 8.5.13 PV string connection
- 8.5.14 Expert menu
- 8.6 Li-Ion battery system functions (MPPT 6000-M only)
- 8.7 NiCd battery system functions (MPPT 6000-M only)
- 8.8 StecaLink bus
- 8.9 Internal data logger
- 8.10 Clear log data
- 8.11 Clear event log
- 8.12 Factory settings
- 8.13 UART/RS-232 interface (MPPT 6000-M only)
- 8.14 Acoustic alarm
- 8.15 SD card (MPPT 6000-M only)
- 9 Control functions via AUX 1/2/3 (MPPT 6000-M only)
- 10 Troubleshooting
- 11 Maintenance, dismounting and disposal
- 12 Technical data
- 13 Guarantee conditions, exclusion of liability, contacts, notes

Signal/Information Value Units Action
RS-232 Data info 9 Total charge/
discharge current of
battery
A
n Current information according to
the sources selected in the
member list in ‘Menu è Settings
è Battery è Control mode è ’
n Currents of the selected sources
are added according to their prefix
n Charge current is displayed as
positive ("+")
n Discharge current is displayed as
negative ("−")
RS-232 Data info 10 PV1 current A Current at module connection M1
RS-232 Data info 11 PV2 current A Current at module connection M2
RS-232 Data info 12 Module current A "#" – Information not present in MPPT
6000-M and MPPT 6000-S
RS-232 Data info 13 Total charge current
of battery
Total of the selected energy input
sources
RS-232 Data info 14 Load current A "#" – Information not present in MPPT
6000-M and MPPT 6000-S
RS-232 Data info 15 Total discharge
current of battery
A Total of the selected energy output
sources
RS-232 Data info 16 Temperature °C
n Temperature of the internal sensor
or
n Temperature of the external
battery temperature sensor, if
connected
RS-232 Data info 17 Error Error state: 0-No errors, 1-Information,
2-Warning
, 3-Error
RS-232 Data info 18 Charging mode
n "#" If the device is OFF or during
the battery capacity test
n Charge mode identifier, F,B,E,L,A,I
RS-232 Data info 19 AUX 1 Switching state of AUX 1 relay
0-OFF, 1-ON
RS-232 Data info 20 AUX 2 Switching state of AUX 2 relay
0-OFF, 1-ON
RS-232 Data info 21 AUX 3 Switching state of AUX 3 relay
0-OFF, 1-ON
RS-232 Data info 22 Energy input 24 h Ah Ah meter of the energy input members
total during the period from 00:00 to
23:59
756.404 | Z01 | 16.06