User manual
Table Of Contents
- 1 General information
- 2 Quick guide
- 3 Overview
- 4 Installation of the base system
- 5 Initial commissioning of the base system
- 6 Installation and initial commissioning of optional components
- 6.1 Commissioning the SD card (MPPT 6000-M only)
- 6.2 AUX 1,2,3 relay output connection (MPPT 6000-M only)
- 6.3 AUX IO remote control input connection (MPPT 6000-M only)
- 6.4 PA TS-S external temperature sensor connection
- 6.5 StecaLink slave connection
- 6.6 StecaLink master connection (MPPT 6000-M only)
- 6.7 UART/RS-232 interface connection (MPPT 6000-M only)
- 6.8 Redundancy function (MPPT 6000-S only)
- 6.9 Install cable strain relief
- 7 Display (layout, function, operation)
- 8 System functions
- 8.1 Protection functions
- 8.2 Battery type setting
- 8.3 Current limit system setting (MPPT 6000-M only)
- 8.4 Current limit device setting
- 8.5 Lead-acid battery system functions
- 8.5.1 Equalisation cycle mode
- 8.5.2 Battery control mode (MPPT 6000-M only)
- 8.5.3 Battery capacity test (MPPT 6000-M only)
- 8.5.4 Battery type
- 8.5.5 Battery capacity
- 8.5.6 Current limit system (MPPT 6000-M only)
- 8.5.7 Current limit device
- 8.5.8 Charge voltages
- 8.5.9 IUIA charge mode (MPPT 6000-M only)
- 8.5.10 Start boost charge
- 8.5.11 Battery temperature sensor
- 8.5.12 Cable compensation
- 8.5.13 PV string connection
- 8.5.14 Expert menu
- 8.6 Li-Ion battery system functions (MPPT 6000-M only)
- 8.7 NiCd battery system functions (MPPT 6000-M only)
- 8.8 StecaLink bus
- 8.9 Internal data logger
- 8.10 Clear log data
- 8.11 Clear event log
- 8.12 Factory settings
- 8.13 UART/RS-232 interface (MPPT 6000-M only)
- 8.14 Acoustic alarm
- 8.15 SD card (MPPT 6000-M only)
- 9 Control functions via AUX 1/2/3 (MPPT 6000-M only)
- 10 Troubleshooting
- 11 Maintenance, dismounting and disposal
- 12 Technical data
- 13 Guarantee conditions, exclusion of liability, contacts, notes

Equipment and design
Connection terminals "M1+/-"; "M2+/-"; "B+/-";
"PE"
35 mm
2
/AWG 2
Dimensions (X x Y x Z) 295 x 335 x 125 mm
Weight 6.3 kg
Display
Type S/W graphical display with backlighting
Resolution 128 x 64 pixels
Accessories
PA TS-S
Type 5 kOhm +/- 2 % NTC
Cable length 2.8 m cable
Plug 2-pin Phoenix Contact RM3.81, Type: MC 1.5/2-
ST-3.81
Termination plug RJ45, 120 Ohm
Battery voltage sensor cable connection
Plug 2-pin Phoenix Contact RM3.81, Type: MC 1.5/2-
ST-3.81
Recommended external battery fuse per PPT
Fuse rating 63 A DC, slow-blow
Recommended external fuse for battery voltage sensor cable
Fuse rating
E.g. 0.75 mm
2
, 1 A; select a fuse rating
appropriate for the wire cross-section used.
1)
Solar module performance data is temperature-dependent. Note the following regarding the
maximum input voltage when selecting the solar module: At temperatures <25 °C the open-circuit
module voltage is higher than the value specified on the type plate.
2)
The scope of language versions may vary with the software version and device variant.
3)
Subject to change without notice.
4)
From software version PU-APP 1.2.0. onwards.
NOTICE!
Technical data that varies from the above is given on a device label. Subject to change without
notice.
756.404 | Z01 | 16.06
137