Configurable auxiliary contacts AUX 1–3 (MPPT 6000-M only)
Excess energy control hysteresis for battery
type: NiCd
Value range depends on the number of cells.
Setting as total battery voltage.
Factory setting 0.057 V/cell [0.4 VDC with number of cells = 7]
Setting range 0.1 VDC … 0.5 V/cell
Timer 1-4
Factory setting Day: none | Switch-off time 00:00 | Switch-on
time 00:00
Setting range Day: MON … SUN | Switch-on time 00:00 …
23:59 | Switch-off time 00:00 … 23:59
Evening light
Factory setting Switch-on delay 00:00 | Switch-on duration
00:01
Setting range Switch-on delay 00:00 … 12:00 | Switch-on
duration 00:00 … 16:00
Night light
Factory setting Switch-on delay 00:00 | Switch-off delay 00:00
Setting range Switch-on delay 00:00 … 12:00 | Switch-off
delay 00:00 … 16:00
Morning light
Factory setting Switch-on duration 00:01 | Switch-off duration
00:00
Setting range Switch-on duration 00:00 … 16:00 | Switch-off
delay 00:00 … 12:00
AUX IO (MPPT 6000-M only)
Plug 3-pin Phoenix Contact RM3.81, Type: MC 1.5/3-
ST-3.81; (fine strand) 0.14 mm
2
-1.5 mm
2
-
AWG 28 - 16
Permissible external signal voltage 5.0 VDC … 24 VDC
Current consumption from external signal
voltage
0.5 mA … 3.0 mA
Required external normally-open contact rating Min. 15.0 VDC; max. 5.0 mA
Mode AUX IO
Factory setting Ext. switch on
Setting range Ext. voltage on | Ext. voltage off | Ext. switch
on | Ext. switch off
756.404 | Z01 | 16.06
133