Configurable auxiliary contacts AUX 1–3 (MPPT 6000-M only)
Generator control starting threshold for battery
type: NiCd
Value range depends on the number of cells.
Setting as total battery voltage.
Factory setting 1.2 V/cell [8.4 VDC with number of cells = 7]
Setting range 1.0 V/cell… 1.7 V/cell
Generator control hysteresis for battery type:
NiCd
Value range depends on the number of cells.
Setting as total battery voltage.
Factory setting 0.057 V/cell [0.4 VDC with number of cells = 7]
Setting range 0.1 VDC … 0.5 V/cell
Excess energy control starting threshold for
battery type: Lead acid, Lead Gel/AGM
SOC | Voltage control
Factory setting 90 % | 13.8 VDC/27.6 VDC/41.4 VDC/55.2 VDC/
69.0 VDC
Setting range 30 % … 100 % | 12.0 VDC … 15.6 VDC/24.0
VDC … 31.2 VDC/36.0 VDC … 46.8 VDC/48.0
VDC … 62.4 VDC/60.0 VDC … 78.0 VDC
Excess energy control hysteresis for battery
type: Lead acid, Lead Gel/AGM
SOC | Voltage control
Factory setting 10 % | 0.9 VDC/1.8 VDC/2.7 VDC/3.6 VDC/4.5
VDC
Setting range 5 % … 70 % | 0.3 VDC … 3.0 VDC/0.5 VDC …
6.0 VDC/0.8 VDC … 9.0 VDC/1.0 VDC … 12.0
VDC/1.3 VDC … 15.0 VDC
Excess energy control starting threshold for
battery type: Li-Ion
Value range depends on the number of cells.
Setting as total battery voltage.
Factory setting 4.1 V/cell [28.7 VDC with number of cells = 7]
Setting range 0.5 V/cell… 7.0 V/cell
Excess energy control hysteresis for battery
type: Li-Ion
Value range depends on the number of cells.
Setting as total battery voltage.
Factory setting 0.3 V/cell [2.1 VDC with number of cells = 7]
Setting range 0.1 VDC … 1.5 V/cell
Excess energy control starting threshold for
battery type: NiCd
Value range depends on the number of cells.
Setting as total battery voltage.
Factory setting 1.6 V/cell [11.2 VDC with number of cells = 7]
Setting range 1.0 V/cell… 1.7 V/cell
756.404 | Z01 | 16.06
132