NiCd battery settings (MPPT 6000-M only)
Temp. factor U1 (>0 °C)
Factory setting -2.5 mV/cell/K/cell
Setting range -6.0 mV/cell/K/cell … 0.0 mV/cell/K/cell
Fixed DOD value
Factory setting 0.00
Setting range 0.00 … 1.00
U1 tolerance for timer
Factory setting 50 mV
Setting range 0 mV … 100 mV
Charging time U1
Factory setting 50 min
Setting range 0 min … 600 min
DOD level charge reset
Factory setting 0.02
Setting range 0.00 … 0.10
Lower charge voltage U2
Factory setting 1.50 V/cell
Setting range 1.35 V/cell… 1.60 V/cell
Temp. factor U2 (>0 °C)
Factory setting 0.0 mV/cell/K/cell
Setting range -6.0 mV/cell/K/cell … 0.0 mV/cell/K/cell
Temp. factor U2 (<0 °C)
Factory setting -2.5 mV/cell/K/cell
Setting range -6.0 mV/cell/K/cell … 0.0 mV/cell/K/cell
Number of NiCd cells
Factory setting 7 cells
Setting range 6 … 50 cells
U2 U1 switch
Factory setting 1.0 V/cell
Setting range 1.0 V/cell… 1.8 V/cell