Li-Ion battery settings (MPPT 6000-M only)
Factory setting 4.00 V/cell
Setting range 1.50 V/cell… 7.00 V/cell
Charge duration
Factory setting 60 min
Setting range 30 min … 120 min
Temperature range
Factory setting Min: 0 °C | Max. 60 °C
Setting range Min: -20 °C … +10 °C | Max : +40 °C … +80 °C
Battery temperature sensor
Factory setting Internal
Setting range Internal/External
Cable compensation
Factory setting Off
Setting range On/Off
NiCd battery settings (MPPT 6000-M only)
Upper charge voltage U1
Factory setting 1.50 V/cell
Setting range 1.35 V/cell… 1.80 V/cell
Limit for charge volt. U1
Factory setting 1.65 V/cell
Setting range 1.5 V/cell… 2.0 V/cell
Lower DOD limit
Factory setting 0.05
Setting range 0.00 … 0.20
U1 factor per DOD
Factory setting 5 mV
Setting range 0 mV … 20 mV
Temp. factor U1 (>0 °C)
Factory setting 0.0 mV/cell/K/cell
Setting range -6.0 mV/cell/K/cell … 0.0 mV/cell/K/cell