User manual

Table Of Contents
8.15 SD card (MPPT 6000-M only)
NOTICE!
For information on handling the SD card, see
Ä
Chapter 6.1 ‘Commissioning the SD card
(MPPT 6000-M only)’ on page 40.
Settings parameters for the MPPT 6000-M can be saved to and read from the SD card.
Various different measurements, states and events can be stored on the SD card.
When data logging is activated the data is recorded in separate files for each StecaLink
member registered at the MPPT 6000-M.
Datalogger On/Off
NOTICES
n Data logging to the SD card can only be generally
switched on and off.
n Any existing data files are not deleted. Information is
appended to existing files.
‘Main menu è SD card è Datalogger On/Off
1. Press SET. The SD Datalogger On/Off dialogue appears
(Fig. left).
2.
Press D, Ñ to change the selection.
3. Press SET. The selection is adopted.
Loading parameters
NOTICES
n Only the entire set of parameters can be loaded.
n The applicable set of valid parameters must be stored in a
file with the name ‘Master.ini’ .
n Selection between various different parameter sets is not
possible.
‘Main menu è SD card è Load parameter
1. Press SET. The Load parameter dialogue appears (Fig. left).
2. Press SET for 1 s. The parameters are then loaded from the SD
card and adopted as the settings for the MPPT 6000-M.
756.404 | Z01 | 16.06