Energy input
Total
NOTICES
n Total amount of energy loaded into the device since initial
commissioning.
n A graphical overview is not possible.
‘Main menu è Internal data logger è Energy input è Total’
1. Press SET. An information window appears (Fig. left).
2. Press ESC. Navigate back to selection.
Energy input
Settings
NOTICES
n This dialogue is used for selecting the devices whose
current/power information is to be included in the energy
input data logging.
n Only the information sources selected in this list are used
for determining the energy input values.
‘Main menu è Internal data logger è Energy input
è Configuration
1. Press SET, the Energy input members dialogue appears
(Fig. left).
2.
Press D, Ñ to change the selection.
3. Press SET. The check box is activated or deactivated
accordingly and the selection is adopted.
4. Press ESC. Navigate back to the Configuration menu.
8.9.2 Energy output (MPPT 6000-M only)
n Record of the information on the amount of output energy in Ah. Optional StecaLink members
such as PA HS400 current sensors are required in addition to the MPPT 6000-M in order to
register discharging of the battery.
n Discharge energy values cannot be recorded if no additional devices for measuring discharge
currents are present.
n The following points can be selected in the Energy output menu:
Last 18 hours,
Ä
‘Energy output’ on page 95
Day,
Ä
‘Energy output’ on page 95
Month,
Ä
‘Energy output’ on page 95
Year,
Ä
‘Energy output’ on page 96
Total,
Ä
‘Energy output’ on page 96
Configuration,
Ä
‘Energy output’ on page 97