NOTICE!
A PA TS-S external temperature sensor is supplied with the device (MPPT 6000-M only).
An event message of type Error is generated if the external temperature sensor is activated
but not connected.
If the controller and battery are not located in the same room then an external temperature
sensor for measuring the battery temperature must be installed. The polarity of the contacts for
the connection is irrelevant.
1. Mount the Steca PA TS-S temperature sensor close to the battery.
2. Insert the sensor cable plug into the TEMP connection (polarity irrelevant!). See
Fig. 2.
Activating an external temperature sensor
u
Press ESC for 1 s. The standard status display appears.
1. Press SET. The Main menu appears.
2.
Press D, Ñ as required to select Battery settings (Fig. left).
3. Press SET. The Battery settings menu appears (Fig. left).
4.
Press D, Ñ to select Bat. temperature sensor.
5. Press SET. The Bat. temperature sensor dialogue appears
(Fig. left).
6.
Press D, Ñ to select External.
7. Press SET. The external temperature sensor is now activated.
8. Press ESC for 1 s. The standard status display appears.