User manual
Table Of Contents
- 1 General information
- 2 Quick guide
- 3 Overview
- 4 Installation of the base system
- 5 Initial commissioning of the base system
- 6 Installation and initial commissioning of optional components
- 6.1 Commissioning the SD card (MPPT 6000-M only)
- 6.2 AUX 1,2,3 relay output connection (MPPT 6000-M only)
- 6.3 AUX IO remote control input connection (MPPT 6000-M only)
- 6.4 PA TS-S external temperature sensor connection
- 6.5 StecaLink slave connection
- 6.6 StecaLink master connection (MPPT 6000-M only)
- 6.7 UART/RS-232 interface connection (MPPT 6000-M only)
- 6.8 Redundancy function (MPPT 6000-S only)
- 6.9 Install cable strain relief
- 7 Display (layout, function, operation)
- 8 System functions
- 8.1 Protection functions
- 8.2 Battery type setting
- 8.3 Current limit system setting (MPPT 6000-M only)
- 8.4 Current limit device setting
- 8.5 Lead-acid battery system functions
- 8.5.1 Equalisation cycle mode
- 8.5.2 Battery control mode (MPPT 6000-M only)
- 8.5.3 Battery capacity test (MPPT 6000-M only)
- 8.5.4 Battery type
- 8.5.5 Battery capacity
- 8.5.6 Current limit system (MPPT 6000-M only)
- 8.5.7 Current limit device
- 8.5.8 Charge voltages
- 8.5.9 IUIA charge mode (MPPT 6000-M only)
- 8.5.10 Start boost charge
- 8.5.11 Battery temperature sensor
- 8.5.12 Cable compensation
- 8.5.13 PV string connection
- 8.5.14 Expert menu
- 8.6 Li-Ion battery system functions (MPPT 6000-M only)
- 8.7 NiCd battery system functions (MPPT 6000-M only)
- 8.8 StecaLink bus
- 8.9 Internal data logger
- 8.10 Clear log data
- 8.11 Clear event log
- 8.12 Factory settings
- 8.13 UART/RS-232 interface (MPPT 6000-M only)
- 8.14 Acoustic alarm
- 8.15 SD card (MPPT 6000-M only)
- 9 Control functions via AUX 1/2/3 (MPPT 6000-M only)
- 10 Troubleshooting
- 11 Maintenance, dismounting and disposal
- 12 Technical data
- 13 Guarantee conditions, exclusion of liability, contacts, notes

Information/column Value
Ibat_total[A]SOC
n Current information according to the sources selected in the
member list in ‘Menu è Settings è Battery è Control mode è .’
n The currents of the selected sources are added according to their
prefix.
n Charge current is displayed as positive ( ‘+’ )
n Discharge current is displayed as negative ( ‘
−’ )
Icharge_total[A] Total of the selected energy input sources.
Iload_total[A] Total of the selected energy output sources.
BatPower_total[W] Total charge/discharge power according to the sources selected in the
member list in ‘Menu è Settings è Battery è Control mode è .’
BatTemp[°C]
n Value of the external battery temperature sensor, if connected.
n ‘-’ if no value is present.
ChargeMode
n ‘OFF’ if the device is OFF or during the battery capacity test.
n Charge mode identifier: F,B,E,L,A,I.
ErrorState Error state: 0-No errors, 1-Information, 2-Warning, 3-Error.
ErrorNr
n Error code
n "-" if no value is present.
StateAux1 Switching state of AUX 1 relay
0 OFF, 1 ON
StateAux2 Switching state of AUX 2 relay
0 OFF, 1 ON
StateAux3 Switching state of AUX 3 relay
0 OFF, 1 ON
IntTemp1[°C] Internal device temperature string 1.
IntTemp2[°C] Internal device temperature string 2.
Derating 0 - Derating not active, 1- Derating active.
Ah_in_24h_M[Ah] Ah meter of the energy loaded through the MPPT 6000-M during the
period from 00:00 to 23:59.
Ah_in_total_M[Ah] Ah meter of the total energy loaded through the MPPT 6000-M since
initial commissioning.
Ah_in_24h_SYS[Ah] Ah meter of the energy input members total during the period from
00:00 to 23:59.
Ah_in_total_SYS[Ah] Ah meter of the energy input members total since initial commissioning.
Ah_out_24h_SYS[Ah] Ah meter of the energy output members total during the period from
00:00 to 23:59.