User manual
Table Of Contents
- 1 General information
- 2 Quick guide
- 3 Overview
- 4 Installation of the base system
- 5 Initial commissioning of the base system
- 6 Installation and initial commissioning of optional components
- 6.1 Commissioning the SD card (MPPT 6000-M only)
- 6.2 AUX 1,2,3 relay output connection (MPPT 6000-M only)
- 6.3 AUX IO remote control input connection (MPPT 6000-M only)
- 6.4 PA TS-S external temperature sensor connection
- 6.5 StecaLink slave connection
- 6.6 StecaLink master connection (MPPT 6000-M only)
- 6.7 UART/RS-232 interface connection (MPPT 6000-M only)
- 6.8 Redundancy function (MPPT 6000-S only)
- 6.9 Install cable strain relief
- 7 Display (layout, function, operation)
- 8 System functions
- 8.1 Protection functions
- 8.2 Battery type setting
- 8.3 Current limit system setting (MPPT 6000-M only)
- 8.4 Current limit device setting
- 8.5 Lead-acid battery system functions
- 8.5.1 Equalisation cycle mode
- 8.5.2 Battery control mode (MPPT 6000-M only)
- 8.5.3 Battery capacity test (MPPT 6000-M only)
- 8.5.4 Battery type
- 8.5.5 Battery capacity
- 8.5.6 Current limit system (MPPT 6000-M only)
- 8.5.7 Current limit device
- 8.5.8 Charge voltages
- 8.5.9 IUIA charge mode (MPPT 6000-M only)
- 8.5.10 Start boost charge
- 8.5.11 Battery temperature sensor
- 8.5.12 Cable compensation
- 8.5.13 PV string connection
- 8.5.14 Expert menu
- 8.6 Li-Ion battery system functions (MPPT 6000-M only)
- 8.7 NiCd battery system functions (MPPT 6000-M only)
- 8.8 StecaLink bus
- 8.9 Internal data logger
- 8.10 Clear log data
- 8.11 Clear event log
- 8.12 Factory settings
- 8.13 UART/RS-232 interface (MPPT 6000-M only)
- 8.14 Acoustic alarm
- 8.15 SD card (MPPT 6000-M only)
- 9 Control functions via AUX 1/2/3 (MPPT 6000-M only)
- 10 Troubleshooting
- 11 Maintenance, dismounting and disposal
- 12 Technical data
- 13 Guarantee conditions, exclusion of liability, contacts, notes

Lead acid/Lead Gel/AGM settings
Float charge completion of charging voltage for
battery type: Lead acid/Lead Gel/AGM
Factory setting 14.1 VDC/28.2 VDC/42.3 VDC/56.4 VDC/70.5
VDC
Setting range 12.6 VDC ... 14.4 VDC/25.2 VDC ... 28.8 VDC/
37.8 VDC ... 43.2 VDC/50.4 VDC ... 57.6 VDC/
63.0 VDC ... 72.0 VDC
Boost charge switch-on threshold for battery
type: Lead acid/Lead Gel/AGM
SOC (MPPT 6000-M only) | Voltage control
Factory setting 70 % | 12.7 V/25.4 V/38.1 V/50.8 V/63.5 V
Setting range 40 % ... 70 % | 11.4 VDC ... 12.7 VDC/22.8
VDC ... 25.4 VDC/34.2 VDC ... 38.1 VDC/45.6
VDC ... 50.8 VDC/57.0 VDC ... 63.5 VDC
Boost charge completion of charging voltage
for battery type: Lead acid/Lead Gel/AGM
Factory setting 14.4 VDC/28.8 VDC/43.2 VDC/57.6 VDC/
72.0 VDC
Setting range 13.2 VDC ... 15.6 VDC/26.4 VDC ... 31.2 VDC/
39.6 VDC ... 46.8 VDC/52.8 VDC ... 62.4 VDC/
66.0 VDC ... 78.0 VDC
Boost charge duration for battery type: Lead
acid/Lead Gel/AGM
Factory setting 120 min
Setting range 0 min ... 300 min
Equalise charging switch-on threshold for
battery type: Lead acid/Lead Gel/AGM
SOC (MPPT 6000-M only) | Voltage control
Factory setting 40 % | 12.2 V/24.4 V/36.6 V/48.8 V/61.0 V
Setting range 10 % ... 60 % | 10.8 VDC ... 12.6 VDC/21.6
VDC ... 25.2 VDC/32.4 VDC ... 37.8 VDC/43.2
VDC ... 50.4 VDC/54.0 VDC ... 63.0 VDC
Equalise charging completion of charging
voltage for battery type: Lead acid
Factory setting 15.0 VDC/30.0 VDC/45.0 VDC/60.0 VDC/75.0
VDC
Setting range 13.8 VDC ... 15.9 VDC/27.6 VDC ... 31.8 VDC/
41.4 VDC ... 47.7 VDC/55.2 VDC ... 63.6 VDC/
69.0 VDC ... 79.5 VDC
Duration of equalise charging for battery type:
Lead acid
Factory setting 240 min
756.404 | Z01 | 16.06
126