User manual
Table Of Contents
- 1 General information
- 2 Quick guide
- 3 Overview
- 4 Installation of the base system
- 5 Initial commissioning of the base system
- 6 Installation and initial commissioning of optional components
- 6.1 Commissioning the SD card (MPPT 6000-M only)
- 6.2 AUX 1,2,3 relay output connection (MPPT 6000-M only)
- 6.3 AUX IO remote control input connection (MPPT 6000-M only)
- 6.4 PA TS-S external temperature sensor connection
- 6.5 StecaLink slave connection
- 6.6 StecaLink master connection (MPPT 6000-M only)
- 6.7 UART/RS-232 interface connection (MPPT 6000-M only)
- 6.8 Redundancy function (MPPT 6000-S only)
- 6.9 Install cable strain relief
- 7 Display (layout, function, operation)
- 8 System functions
- 8.1 Protection functions
- 8.2 Battery type setting
- 8.3 Current limit system setting (MPPT 6000-M only)
- 8.4 Current limit device setting
- 8.5 Lead-acid battery system functions
- 8.5.1 Equalisation cycle mode
- 8.5.2 Battery control mode (MPPT 6000-M only)
- 8.5.3 Battery capacity test (MPPT 6000-M only)
- 8.5.4 Battery type
- 8.5.5 Battery capacity
- 8.5.6 Current limit system (MPPT 6000-M only)
- 8.5.7 Current limit device
- 8.5.8 Charge voltages
- 8.5.9 IUIA charge mode (MPPT 6000-M only)
- 8.5.10 Start boost charge
- 8.5.11 Battery temperature sensor
- 8.5.12 Cable compensation
- 8.5.13 PV string connection
- 8.5.14 Expert menu
- 8.6 Li-Ion battery system functions (MPPT 6000-M only)
- 8.7 NiCd battery system functions (MPPT 6000-M only)
- 8.8 StecaLink bus
- 8.9 Internal data logger
- 8.10 Clear log data
- 8.11 Clear event log
- 8.12 Factory settings
- 8.13 UART/RS-232 interface (MPPT 6000-M only)
- 8.14 Acoustic alarm
- 8.15 SD card (MPPT 6000-M only)
- 9 Control functions via AUX 1/2/3 (MPPT 6000-M only)
- 10 Troubleshooting
- 11 Maintenance, dismounting and disposal
- 12 Technical data
- 13 Guarantee conditions, exclusion of liability, contacts, notes

Characterisation of the operating behaviour MPPT 6000-M/MPPT 6000-S
Dynamic MPP efficiency 99.8 %
Max. DC/DC efficiency 99.4 % (UBatt=48 V; UIn=70 V;P=0.65*Pnom)
Own consumption In operation: 2 W; Standby: < 1 W
DC input side
Max. input voltage
1)
150 V/180 V
4)
Module current
1)
2 x 30 A/1 x 60 A
4)
MPP voltage/string
> 1.15 x U bat to 180 V
4)
Open circuit solar module/string voltage 180 V/200 V
(at minimum operating temperature)
4)
DC output side
Max. charging current 60 A
Charge parameters
Battery capacity
Factory setting 100 Ah
Setting range 30 Ah … 50,000 Ah
System current limit (MPPT 6000-M only)
Factory setting Off | 1605.0 A
Setting range Off/On | 5.0 A … 1605.0 A
Maximum device current
Factory setting 60.0 A
Setting range 5.0 A … 60.0 A
Battery type
Factory setting: Lead acid
Setting range Lead acid/Lead Gel/AGM (MPPT 6000-M and
MPPT 6000-S) Li-Ion/NiCd (MPPT 6000-M only)