User manual
Table Of Contents
- 1 General information
- 2 Quick guide
- 3 Overview
- 4 Installation of the base system
- 5 Initial commissioning of the base system
- 6 Installation and initial commissioning of optional components
- 6.1 Commissioning the SD card (MPPT 6000-M only)
- 6.2 AUX 1,2,3 relay output connection (MPPT 6000-M only)
- 6.3 AUX IO remote control input connection (MPPT 6000-M only)
- 6.4 PA TS-S external temperature sensor connection
- 6.5 StecaLink slave connection
- 6.6 StecaLink master connection (MPPT 6000-M only)
- 6.7 UART/RS-232 interface connection (MPPT 6000-M only)
- 6.8 Redundancy function (MPPT 6000-S only)
- 6.9 Install cable strain relief
- 7 Display (layout, function, operation)
- 8 System functions
- 8.1 Protection functions
- 8.2 Battery type setting
- 8.3 Current limit system setting (MPPT 6000-M only)
- 8.4 Current limit device setting
- 8.5 Lead-acid battery system functions
- 8.5.1 Equalisation cycle mode
- 8.5.2 Battery control mode (MPPT 6000-M only)
- 8.5.3 Battery capacity test (MPPT 6000-M only)
- 8.5.4 Battery type
- 8.5.5 Battery capacity
- 8.5.6 Current limit system (MPPT 6000-M only)
- 8.5.7 Current limit device
- 8.5.8 Charge voltages
- 8.5.9 IUIA charge mode (MPPT 6000-M only)
- 8.5.10 Start boost charge
- 8.5.11 Battery temperature sensor
- 8.5.12 Cable compensation
- 8.5.13 PV string connection
- 8.5.14 Expert menu
- 8.6 Li-Ion battery system functions (MPPT 6000-M only)
- 8.7 NiCd battery system functions (MPPT 6000-M only)
- 8.8 StecaLink bus
- 8.9 Internal data logger
- 8.10 Clear log data
- 8.11 Clear event log
- 8.12 Factory settings
- 8.13 UART/RS-232 interface (MPPT 6000-M only)
- 8.14 Acoustic alarm
- 8.15 SD card (MPPT 6000-M only)
- 9 Control functions via AUX 1/2/3 (MPPT 6000-M only)
- 10 Troubleshooting
- 11 Maintenance, dismounting and disposal
- 12 Technical data
- 13 Guarantee conditions, exclusion of liability, contacts, notes

Event message
Cause Remedy
Type No. Text
Warning
33 MinMax out of
range
Invalid parameter setting
detected. The setting lies
outside the range
defined for the device.
Max./Min. errors can
occur when the setting
ranges of the master and
slave differ due to
different software
versions. The error is
triggered when
transferring settings from
the master to the slave if
the setting from the
master lies outside the
valid setting range for
the slave. This error can
also occur when different
parameter files have
been used for updating
the devices (M/S).
Execute the Factory reset
function. Notify the Service
department if the error persists
and perform a software update if
necessary.
Warning
45 Ext. temp.
sense open
An open-circuit exists in
the external temperature
sensor cable.
Check the following points:
n External temperature sensor
cable correctly connected to
the controller?
n Cable open-circuit?
n External temperature sensor
damaged?
Warning
46 Ext. temp.
sense short
A short-circuit exists in
the external temperature
sensor cable.
Check the following points:
n External temperature sensor
cable correctly connected to
the controller?
n Short circuit in connecting
cable?
n External temperature sensor
damaged?
Warning
53 NTC ambient
open
Failure of the device-
internal temperature
measuring position used
for determining the
ambient temperature of
the battery.
Switch off the temperature
compensation (Expert menu).
Contact the Steca Service
department.
Warning
54 NTC ambient
short
Failure of the device-
internal temperature
measuring position used
for determining the
ambient temperature of
the battery.
Switch off the temperature
compensation (Expert menu).
Contact the Steca Service
department.