User manual
15708.219 | 08.44
Charge controller activation
Activation threshold of the
charge type
SOC Control Voltage control
Float charge SOC >=70 % >=12.7 V resp.
>= 25.4 V
Boost charge SOC
40 % - 69 %
11.7 V - 12.4 V; resp.
23.4 V - 24.8 V
Equalization charge SOC < 40 % < 11.7 V resp. 23.4 V
30 day maintenance
charge
if within 30 days no equalization or boost
charge was active.
Load disconnection
SOC Control Voltage control
Early warning load
disconnection
SOC <40 % < 11.7 V / 23.4 V
Load disconnection SOC <30 % < 11.1 V / 22.2 V
Load reconnection SOC >50 % > 12.6 V / 25.2 V
Mechanical Data
Protection type IP 32
Installation wall installation
Weight 350 g
Housing recycledable, plastic housing
Dimensions L x B x H 187 x 96 x 44 mm
Fastening
hole clearance
vertical 60 mm; horizontal 177 mm
Terminals
(fine / strand)
16 mm²/ 25 mm² / AWG: 6 / 4 mm²