Specification Sheet
IMPORTANT:
INSTALL WITH ARROWS POINTING UP
WARNING: Unit must be installed
INDOORS, in a DRY, NON-FREEZING
location and with arrows pointing up.
Service by authrorized personnel only.
NOTE: Read all instructions before installation
CAUTION: To prevent internal damage hold all fittings
securely while making plumbing connections.
NOTE: See Wiring Diagram on reverse side of cover.
CAUTION: Turn off electric before removing cover.
NOTE: This is NOT intended to be used for space
heating purposes.
009-1081
¾" Steam Outlet
⅜" Water Inlet
Safety Relief Valve
Auto Drain
Typical Steam Generator
2"
24"
¾" MGHT Male Threaded NPT
or 1/2" NPT Female
Floor Drain:
Minimum air gap is
twice the effective
diameter of the
discharge pipe
Air Gap
Steam Head
Pan Pipe
Generator Pan
Generator Pan
Model: SM-DP
Generator Pan
Installation Instructions
01/14
Pub. No. 304-D
Typical Installation
Generator Pan Installation
1. Place the SM-DP generator pan on a flat surface
suitable for the Steam Generator (Pan dimensions 24"
x 11" x 2"H)
2. The generator pan pipe must be ran in a manner as to
not obstruct any possible flow of water out of the pan.
3. The generator pan pipe must terminate over a suitable
waste receptor or extended outside the building in an
observable location. The termination point must be at
least 6”, but not more than 24” above ground level.
4. The plumbing installation must conform to all local and
national codes.
5. The generator pan pipe must be run in a continuous
downward slope to acheive adequate drainage.
Termination of the drain line must allow complete
drainage at all times, and not be affected by freezing
temperatures.
6. See separate plumbing and auto drain installation
manuals for complete connection details.
®