Technical Specifications
elements will stop heating and the water inlet valve will work automatically. If there is
no water detected in 20 seconds or the water coming in does not reach the set point in
60 seconds, the digital tube will display to indicate an error of not enough water
cycling. If there is enough water cycling, the steam function will return to normal.
When the steam function is started, if the ambient room temperature is higher than the
set point, the heating element will stop heating, the digital tube will flash to display the
current environment temperature; when the environment temperature is lower than the
set point, the heating element will work again, the digital tube will display current
room temperature normally.
When the system is on, press button to turn off the system, or when the steam time
is over the system shuts off 10 minutes after the system is shut off, the drainage
function will be started automatically for 7 minutes.
when the steam generator is working, water inlet shall not be cut off.
!
Important:
3. TIME AND TEMPERATURE SETTING
When system is on, press button twice, system will cycle switch in time setting,
TEMP setting and ambient TEMP display state.
When the digital tube displays dashes across the screen it will allow you to set the
duration of the steam bath. During this time, press or to adjust steam time.
Its range is 1-60 minutes, with 1 minute intervals. If there is no adjustment in 5
seconds, the system will exit time setting automatically and the LED will display
current ambient TEMP.
When the LED screen shows number and TEMP unit “℉ (℃ )”, it is displaying the
indoor ambient temperature. When the TEMP unit F flashes on the LED screen, it
means the system is in the steam TEMP setting state. During this time, press
or to adjust steam TEMP. Its range is 50°~130° Fahrenheit, with 1° increments.
If no adjustment is done in 5 seconds, the system will exit the TEMP setting
automatically and the LED screen will display ambient temperature.
Page 4
4. MEMOMY FUNCTION
When the system is on, it recalls the last time used with the steam time and TEMP.
When the system is on, after adjusting steam time and steam TEMP, press for
about 1.5 seconds to adjust time and TEMP parameters as current state. The LED
screen will show current settings.
When system is on, press to switch modes between SET1 and SET2. The LED
screen displays the current mode.
GS08A