Installation Guide
Rev1/2015 
10 | P a g e  
Turn on the water and test. Of the unit still leaks, replace the 
cartridge (E). 
 Make sure that both hot and cold water inlets are turned 
on. 
 Water flow is very low. 
Check the cartridge assembly (D), for debris. Sediment where 
the water enters the shower head (G) can also cause this 
symptom. 
 Water starts out hot and becomes cooler as handle is 
rotated counter clockwise. 
This is a potentially hazardous situation and should be corrected 
before using the unit. Check the hot and cold inlet positions (hot-
left, cold-right). If you have a back to back installation, (where hot 
and cold inlets are reversed) refer to valve body instruction sheet 
for back to back installation. 
 Water flows from the shower head while filling the tub. 
Check the position of the valve body (J). The letters SHWR 
should be vase into the top and TUB on the bottom. 
 Water doesn’t get hot enough. 
Remove hand (A), sleeve (B) and flange (C) and then refer to 
valve body instruction sheets for adjusting temperature range. 
 Water flows from the tub spout while using the shower. 
The seal inside of the diverter mechanism may have become 
dislodged. The spout (H) may need replacement. 
CLEANING CARTRIDGE 
If temperature or flow does not remain constant, the cartridge 
assembly (A) must be cleaned. Shut-off water supply. Remove 
trip assembly (not shown). Remove screws (C), backup plate (B) 
and cartridge assembly (A). inspect inlets for sediment and flush 
with water. Inspect O-rings (D & E) for damage. Re-install 
cartridge assembly (A) and backup plate (B) then turn on water 
supply. If the problem persists replace cartridge assembly (A). 
CAUTION: Do not disassemble cartridge (A).  
CLEANING AND MAINTENANCE FOR ALL UNITS 
1.  Liquid detergents and soft cloth should be used. Do not use any 
abrasive cleaners. 
2.  The scale on the surface can be cleaned with a soft cloth and 
nonabrasive cleaner or heated vinegar. 
3.  After every 30 uses, we suggest you to clean the steam generator. 
We advise the use a filtration system for the steam generator unit.  
One Compatible filtration system option is the -Whirlpool WHKF-DWHV 
STEAM GENERATOR CLEANING FOR ALL UNITS 
Remove  the  cover  of  the  cleaning  liquid  inlet  and  pour  in 
approximately 1L of citric acid or white vinegar. Start the steam 
function  to  fill  the  steam  generator  with  water.  Stop  the  steam 
function  before  the  steam starts  to  come  out  (“acidic” steam  is 
damaging to plated fixtures). Do not shut off the main power. The 
scale in the steam generator dissolves and the system drains the 
dirty water out after 60 minutes.  
GENERAL USE AND MAINTENANCE FOR ALL UNITS 
A.  Drops of water will continue to drain out from the jets and water outlets after use, this is normal and it will eventually stop. 
B.  Abrasive cleaners must not be used. 
C.  Always shut off the power supply when the system is not in use. 