Installation Guide
10 
.
PFISTER HANDLE ASSEMBLY 
TRIM FLANGE ATTACHMENT 
Position Flange (A) on the Valve (B) with drain hole (C) at the 
bottom. Place Protective Washer (D) on the short end of the 
reversible Retainer Sleeve (E). Screw Retainer Sleeve (E) onto 
threaded section of the Stem and Bonnet (G). Tighten Retainer 
Sleeve (E) by hand until Flange (A) is snug to finished wall surface. 
If the short end of the Retainer Sleeve (E) is too short, reverse it to 
use the longer end. 
HANDLE ATTACHMENT 
Screw Stem Extender (A) onto the Valve Stem (B). Thread the Set 
Screw (C) into the Handle and thread it in only three or four turns. 
With valve in CLOSED position, place handle (D) onto the Steam 
Extender (A) and tighten the Set Screw (C) by using the Hex 
Wrench (E) that is provided. 
Note: Make sure Set Screw (C) is securely tighten to handle (D). 
TEMPERATURE ADJUSTMENTS 
Adjustment gear (A) is factory-set to prevent stem from reaching 
full hot position. To adjust stem rotation: remove adjustment gear 
(A). Rotated steam (B) counterclockwise to determine a 
maximum desired temperature. Replace gear aligning 
adjustment stop (C) to stem tab surface (D) to stem (B) cannot 
move beyond adjustment point. 