Installation Guide
3 pg 
Choose your size of machine  
Measure the length, width, and height in feet of the current steam shower or bathtub room. 
Example; L:7 x W:5 x H:8 = 280 Cubic feet x 2 to get complete cubic measurement  
Note: Multiplying the cubic feet by two is done to account for heat loss due to the room having natural stone such as 
granite or marble, exterior walls, ceiling height exceeding 8 feet, ceramic tile, or glass walls. 
Refer to the Parameter section to know if you have the correct size needed for your space. 
Parameter 
Power 
Space 
Voltage 
Breaker Requirement 
Wire DIA 
6kW 
140-320ft³ 
220-240V 
30A 
10# ro 6MM² 
9kW 
320-460ft³ 
220-240V 
50A 
8# ro 8MM² 
12kW 
460-700ft³ 
220-240V 
60A 
6# ro 10MM² 
18kW 
700-920ft³ 
Two 220-240V Lines 
Two 50A breakers 
Two 8# ro 6MM² lines 
24kW 
920-1400ft³ 
Two 220-240V Lines 
Two 60A breakers 
Two 6# ro 10MM² lines 
•  110-120V AC power supply for power module GH21-PB 
•  Single power box comes with every size of the generator. Additional keypads and/or generators could be added 
to the same power box. Call for any clarification. 
Dimensions 
Size 
A 
B 
C 
D 
E 
6/9kW 
10 3/8in 
(263.5mm) 
7 7/8in 
(200mm) 
13 1/8in 
(333mm) 
10 7/16in 
(264.5mm) 
14 5/8in 
(372mm) 
12kW 
10 3/4in 
(260mm) 
9 3/8in 
(238mm) 
16 1/8in 
(409mm) 
10 7/16in 
(264.5mm) 
14 5/8in 
(372mm) 