3 SPECIFICATIONS AND ADDITIONAL INFORMATION
3.1 Glossary
ASK Amplitude-Shift Keying
ETSI European Telecommunications Standards Institute
FSK Frequency-Shift Keying
GPRS General Packet Radio Service
ISM Industrial, Scientific and Medical radio band
PPM Pulse Position Modulation
RF Radio Frequency
TPMS Tire Pressure Monitoring System
TPS Tire Pressure Sensor
3.2 Electrical and Functional Specifications
Parameter
Mini
mum
Typical
Maximum
Supply Voltage 4V DC 6V DC 11V DC
Current Absorption
2A @3.6V (peak pulse
during GSM/3G
transmission)
Frequency of TPMS receiver 434.4 MHz
Frequency of Network for collecting
data between Master and Slave
922.4 MHz
Radiated Power (dBµV/m at 3m) 85
Frequency of GSM Module
850/900/1800/1900
MHz
Frequency of 3G Module
850/900/1900/2100
MHz
Operating temperature -20°C +55°C
Expected battery life at average
temperature considering 200 trucks
passing through per day
1 year
3.3 Mother Board Plastic Enclosure Technical Specifications
Fire classification Flame Retardant (UL 94 V-0)
Protection Class IP 66
3.4 Plastic External Shell Of Towers: Technical Specifications
3.5 Battery pack: Technical Specifications
Color white
Material PP GF30
Mechanical dimensions 200 x 200 x 650 mm
Note: Mechanical dimensions may be subject to variations.
Model Duracell PC1300 Size D 1.5V (12pcs)
Nominal voltage 6V (4 x 1.5V)
Capacity 3x15000 mAh
Operating temperature range -20°C to +55°C