Datasheet

SiliVolt-2V
Cables and multistrand wires main catalog 19
Order No.
Type
Nominal cross section
Strand design
Weight of cable
Conductor diameter
Thickness
insulation wall
Outer diameter
Rated voltage
Test voltage
Rated current
Certification marks
*Colours
SIL mm² n x Ø mm kg/km mm mm mm V V AC A
61.7662- * SILI-2V 0,50 0,50 256 x 0,05 10 1,0 0,85 2,7 1500 8000 12
1)
21
22
23
61.7663- * SILI-2V 0,75 0,75 385 x 0,05 17 1,25 1,1 3,5 1500 8000 15
1)
21
22
23
24
25
26
27
28
29
61.7664- * SILI-2V 1,0 1,0 511 x 0,05 21 1,5 1,2 3,9 1500 8000 19
1)
21
22
23
24
25
26
27
28
61.7666- * SILI-2V 2,0 2,0 525 x 0,07 29 2,0 0,95 3,9 1500 8000 30
1)
21
22
23
61.7667- * SILI-2V 2,5 2,5 651 x 0,07 38 2,4 1,1 4,6 1500 8000 32
1)
21
22
23
27
28
Super flexible stranded wire with reinforced,
double-layer insulation for the highest safe-
ty (inside natural, outside coloured). Dam-
age to the outer layer of insulation can be
more easily recognised due to the dierent
colour of the underlying layer. Types ... SN
with tinned wire strands for continuous use
at temperatures up to 150 °C.
Typical Application
Hand-held test leads for maximum safety
requirements and high thermal stress.
1)
UL recognized: File E120880
Use: Test Probe Lead up to +60 °C
SiliVolt-2V