WARNINGS
•Installationbyaqualiedprofessionalishighlyrecommended.
•Donotbegininstallationuntiltheseinstructionshavebeenthoroughly
read and understood.
•Thisceilingplatesupportsa maximum load of 90 lbs (40.82 kg).
•Themanufacturerdoesnotacceptresponsibilityforincorrectinstallation.
TOOLS REQUIRED
•PowerDrill
•5/32”(4mm)Drillbit
•1/4”(6mm)MasonryBit
•13/32”SocketHeadWrench
INSTALLATION INSTRUCTIONS
Step 1: Install the Flush Mount Tube
a. From the top, thread the Flush Mount Tube
through Retaining Collar in Ceiling Tray.
Step 2: Install the Ceiling and Filler Trays
a.PlaceCeilingTrayinto24”(610mm)x24”(610mm)
opening in ceiling (in place of a ceiling tile) with Retaining
Collar to the right or left.
b. Place Filler Tray into gap.
c. Attach Ceiling Tray to Filler Tray using four Screws
and four Nuts.
Step 3: Install the Wire Supports
a. Insert Turnbuckle hooks into four corners of Ceiling Tray.
b. Cut TieWireintofourpiecesofequallengthand
insert wires through the ends of the Turnbuckles.
c. Twist each wire around itself several times
(minimum of 6-8 times recommended)
as tightly as possible.
 d.DrillholesforfourCeilingAnchors
based on material:
Wood Joists or Beams:
  Drill5/32”(4mm)diameter
  holes2”(51mm)deep.
  FullyinsertEyeBolts(Fig4).
Solid Concrete:
  Drill1/4”(6mm)diameter
  holes1.5”(38mm)deep.
  HammerinConcreteAnchors(Fig5).
Truss Ceiling:
  Noanchorrequired.Afterattaching
Tie Wire to Turnbuckle, loop upper end
around ceiling truss. Pull Tie Wire tight
and twist it around itself several times
(minimum of 6-8 times recommended)
as tightly as possible (Fig 6).
Position the holes so when the tie wires are
attached and taut, the optimal angle is 15°.
Unit may be mounted at an angle up to
45° if necessary.
e. Pull Tie Wires tight and attach to ends of ceiling anchors. Twist each wire around
itself several times (minimum of 6-8 times recommended) as tightly as possible.
The weight of the Ceiling Tray should be supported by the Tie Wires.
Note: 20’ (6.1 m) of Tie Wire is provided. If space between the true ceiling and
suspended ceiling is more than 36” (914 mm), additional wire (12 gauge annealed,
steel, black) will be needed.
DO NOT extend two wires together - use one continuous wire.
PARTS INCLUDED
Allen Wrench, 2.5mm,
Security/Non-Security (x1)
Allen Wrench, 4mm (x1)
Tie Wire, 20’ (x1)
Eye Bolt (x4)Turnbuckle (x4)Concrete
Anchor (x4)
1/4”-20 Nut (x4)
Flush Mount
Tube (x1)
Fig 1
Fig 2
1/4”-20 x 3/8”
Screw (x4)
Ceiling Tray (x1) Filler Tray (x1)
Fig 3
Fig 4
Fig 5
Fig 6
Retaining
Collar
M5 x 5mm Set Screw,
Security (x2)
M5 x 5mm
Set Screw (x2)