Datasheet
Equipment qualities
- Linear regulator
- Excess temperature protection
- short-circuit proof
- galvanically separated to input
- automatic switch over cv/cc
- Excess temperature display by LED (type 2224)
- separate LCD for corrent and voltage
- output mass free
- swiching current (type 2223.13)
technical parameter
specification type 2224.81
DC output voltage 0-24V
DC
output current 0-10A
CV stability net +5/-7% <2mV
CV stability load 0-100% 50mV
CV remaining ripple Ueff <1mV
CC stability net +5/-7% <3mA
CC stability load 0-100% 3mA
CC remaining ripple I eff 3mA
correction time load 10-100
%
100µs
adjuster Uoutput / Ioutput 2*
dissolution of adjusting
characteristic
display for U / I
output connector
cooling
swiching current
operating temperature 0 - 35°C
max. relative humidity 85% by 35°C
AC input voltage 230 V +6 / -10% 48-62Hz
AC testing voltages
safety class I
manufactured DIN VDE 0551 ; DIN VDE 0875 Teil 11 curve B; EN 61010; EN 61000-6
dimensions WxHxD mm
weight kg 8,5 kg
1*-
2*- wire-wound potentiometers / wire-wound potentiometers
wire-wound potentiometers / potentiometer 270
°
2* 1*
EN
display tolerance
0-25mA +/-0,5mA; 0-250mA +/-2mA und
0-2,5A +/-10mA +/- 1 Digit
convection
3 step 0- 25mA, 0- 250mA and 0- 2,5A
260x150x230
5,5 kg
185x120x220
4 kg
2223.13
0-30V
0-2,5A
15mV
0,10%
U / I
30mV
<3mA
<4mA
2mA
2mV
2,5mA
5mA
2mA
<2mV
50mV
<2mV
bis 150W
Digital LCD 13mm 3½-digit
controlled regulator
DC voltage regulators
single output
rated power
4mm sockets
2224.9
0-30V
0-5A
D4-2e.xls
STATRON Gerätetechnik GmbH
Ehrenfried-Jopp-Str.59
15517 Fürstenwalde
Tel.:+49 3361 372101
Fax :+49 3361 372103
e-mail:statron@statron.de