Safety data sheet
according to 1907/2006/EC, Article 31
Printing date 24.05.2018 Revision: 24.05.2018Version number 1
Trade name:(6'6SUD\$VWUD6WDW(6'W\SH6
(Contd. of page 3)
45.2.4
·
6.4 Reference to other sections
See Section 7 for information on safe handling.
See Section 8 for information on personal protection equipment.
See Section 13 for disposal information.
SECTION 7: Handling and storage
·
7
.1 Precautions for safe handling
Keep away from heat and direct sunlight.
Ensure good ventilation/exhaustion at the workplace.
Open and handle receptacle with care.
Persons with a history of asthma, allergies or chronic or recurrent respiratory diseases should only be
employed in processes in which this product is used under appropriate medical supervision.
·
Information about fire - and explosion protection:
Do not spray onto a naked flame or any incandescent material.
Keep ignition sources away - Do not smoke.
Protect against electrostatic charges.
Pressurised container: protect from sunlight and do not expose to temperatures exceeding 50°C, i.e. electric
lights. Do not pierce or burn, even after use.
·
7.2 Conditions for safe storage, including any incompatibilities
·
Storage:
·
Requirements to be met by storerooms and receptacles:
Store in a cool location.
Observe official regulations on storing packagings with pressurised containers.
·
Information about storage in one common storage facility:
Do not store together with reducing agents, heavy-metal compounds, acids and alkalis.
Store away from foodstuffs.
·
Further information about storage conditions:
Do not seal receptacle gas tight.
Keep container tightly sealed.
Store in cool, dry conditions in well sealed receptacles.
Protect from heat and direct sunlight.
Store separately from oxidising agents, strongly alkaline and strongly acidic materials, amines, alcohol and
water.
·
Storage class:
2 B
·
7.3 Specific end use(s)
No further relevant information available.
*
SECTION 8: Exposure controls/personal protection
·
Additional information about design of technical facilities:
No further data; see item 7.
·
8.1 Control parameters
·
Ingredients with limit values that require monitoring at the workplace:
115-10-6 dimethyl ether
WEL Short-term value: 958 mg/m³, 500 ppm
Long-term value: 766 mg/m³, 400 ppm
67-64-1 acetone
WEL Short-term value: 3620 mg/m³, 1500 ppm
Long-term value: 1210 mg/m³, 500 ppm
(Contd. on page 5)