State Water Heater Water Heater Brochure

RESIDENTIAL COMBI BOILERS
A hot water tap is opened causing
incoming potable water to flow through
the flat plate heat exchanger.
Heated boiler water, supplied from the
fire tube heat exchanger, flows through
a diverter valve and into the flat plate
heat exchanger where it prioritizes
heating the incoming domestic water to
the designated set point temperature.
The integrated boiler pump circulates
boiler water through the fire tube
heat exchanger to keep it at set point
temperature.
When there is a call for space heating,
the diverter valve directs the heated
boiler water into the external space
heating loop.
With a 10:1 turndown ratio, the
ProLine
®
XE combi boiler has the
ability to modulate combustion
to maximize efficiency and
prevent short cycling when there
are small heating demands.
ENERGY CONSERVATION
The ProLine
®
XE combi boiler
combines space heating and
domestic hot water (DHW) in
one appliance, providing a
space saving choice for builders
and specifying engineers.
COMPACT SIZE
The ProLine
®
XE Combi Boiler
provides up to 74% more
heating capacity than other
combi boilers. For domestic
hot water (DHW), it is also sized
large enough to provide 2.6 gpm
(110 model) to 4.8 gpm (199
model) at a 77°F temperature
rise.
MORE HOT WATER
DOMESTIC HOT WATER AND SPACE HEATING
HOW IT WORKS:
45