State Water Heater Water Heater Brochure

Specifications
Set temperature: 145°F or lower
Set temperature: 150°F or higher
50
40
30
20
10
0
16.014.012.010.08.06.04.02.00.0
25
20
15
10
5
0
0
2
4
6
8
10
12
14
16
25 45 65 85 105 125 145
Set temperature: 145°F or lower
Set temperature: 150°F or higher
910: Flow Rate vs. Temperature Rise
910: Pressure Loss
Indoor and Outdoor Installation Options
Power Vent or Power Direct Vent Design
Low NOx Emissions
Flow Rate up to 14.5 GPM
Values based on factory testing. 0.4 GPM required for
continuous fire after initial ignition
Water Pressure: 15-150 psi
Pressure Only Relief Valve Requires (Min 380,000
btu/h, 150 psi).
40 psi or above recommended for max. flow
Dimensions
Easy-Link up to 4 heaters or connect up to 10 heaters
with a Multi-Unit Controller
Warranty
6-year limited warranty on heat exchanger in
commercial applications.
5-year warranty on all parts.
Refer to StateWaterHeaters.com for further warranty
details
910: Flow Rate vs. Temperature Rise 910: Pressure Loss
Temperature rise (°F)
Flow rate (gpm)
Flow Rate (gpm)
Pressure Loss (psi)
Head (ft)
40