PROBLEMS
NOT ENOUGH HOT WATER
1.)Blowerwillnotrun.
a.“ON/OFF”controlswitchturnedoff. Turnswitchtothe“ON”position.
b.Blowerunplugged. Plugblowerbackinto115VACoutlet.
c.Nopoweratoutlet. Repairservicetooutlet.
d. Thermostat defective. Replacethermostat.
e. Control harness defective. Replacecontrolharness.
f.Highlimitcontrolcircuitopen.
Reducethewatertemperaturebelow140°F.
Turn the power switch to the off position.
Wait 10 seconds.Turn the powerswitch to
theonposition.Reducethe
temperatureset
pointtominimizelikelihoodofreoccurrence.
If
thisdoesnotsolvetheproblem,replacethe
thermostat.
g.Blowermotordefective. Replaceblowerassembly.
2.)Thermostatproblems
a. Thermostat set too low. Adjusttemperaturecontrolhigher.
b. Thermostat or ECO defective Replacethermostat.
3.)Others
a.Heaterundersized.. Reduce hot water use.
b.Lowgaspressure Contact dealer.
c.Incomingwaterisusuallycold. Allow more time for heater to reheat.
d.Leakinghotwaterpipesoffixtures. Haveplumbercheckandrepairleaks.
e. Heater not lit or thermostat not on. Refer to LIGHTING INSTRUCTIONS.
VENT PIPE TOO HOT (ABOVE 170°F [77°C]) Wrongburnerorice. Turnoffheaterandgas,cleanburnerhead.
YELLOW FLAME
Dirtinburnerports. Turnoffheaterandgas,cleanburnerhead.
Combustionairpathrestricted.
Check exhaust venting and air openings
in bottom base pan for obstructions or
blockage.
CONDENSATION Waterontheoorunderheater. See CONDENSATION section.
WATER LEAKS
Improperly sealed, hot or cold supply
connections, relief valve, drain valve or
thermostat threads.
Checkforleaks.SeeFigure1.
Leakagefromotherappliancesorwaterlines.
Inspectotherappliancesnearwaterheater.
Condensationofueproducts. Refer to CONDENSATION section.
LEAKING T & P
Thermalexpansioninclosedwatersystem.
Installthermalexpansiontank(Do notplug
T&Pvalve).
Improperlysealedvalve.
Checkrelief valve forproper operation (Do
notplugT&Pvalve).
HOT WATER ODORS
(refer to cathodic protection)
High sulfate or mineral content in water
supply.
Drainandushheaterthoroughlythenrell.
Bacteriainwatersupply. Chlorinatewatersupply.
HOT WATER TOO HOT Thermostatsettoohigh.
Refer to TEMPERATURE REGULATION
section.
WATER HEATER SOUNDS Condensationdrippingonburner. Refer to CONDENSATION above.
SIZZLING - RUMBLING Sedimentatbottomofheatertank.
Cle an sedi ment fr om ta nk. Refer to
DRAINING.
SOOTING Impropercombustion. Refer to Air Requirements.
BURNER WILL NOT STAY LIT-GOES OUT
4-5 SECONDS
Outletpolarityisreversed. Testpolarityandcorrect.
Highambientroomtemperature.
Contact a qualified service agency to
determine cause.
Defectivegasvalve. Replacegasvalve.
VENT GAS ODORS
Lackofairsupply.
Shut off water heater immediately and contact a
qualiedserviceagencytodeterminecause.
Improperlyinstalledventpiping.
Downdraft
Poor Combustion
TROUBLESHOOTING GUIDELINES
Theseguidelinesshouldbeutilizedbyaqualiedserviceagent.