- Instruction Manual Residential Gas Water Heater

14
Figures2and10showthetypicalattachmentofthewaterpipingto
thewater heater.Thewaterheater is equipped with 3/4 inchNPT
water connections.
NOTE: If using copper tubing, solder tubing to an adapter
before attaching the adapter to the water heater connections.
Do not solder the water lines directly to the water heater
connections. It will harm the dip tube and damage the
tank.
T & P Valve and Pipe Insulation (if supplied)
Remove insulation for T & P valve and pipe connections from
carton.
FIGURE 11.
Fit pipe insulation over the incoming cold water line and the
hot waterline.Makesurethattheinsulationisagainstthetop
coveroftheheater.FitT&Pvalveinsulationovervalve.Make
sure that the insulation does not interfere with the lever of the
T & P valve.
Secureallinsulationusingtape.
TEMPERATURE-PRESSURE RELIEF VALVE
This heater is provided with a properly certified combination
temperature-pressurereliefvalvebythemanufacturer.
The valve is certiedby a nationallyrecognized testing laboratory
thatmaintainsperiodicinspectionofproductionoflistedequipmentof
materialsasmeetingtherequirementsforReliefValvesforHotWater
SupplySystems,ANSIZ21.22•CSA4.4,andthecoderequirements
of ASME.
Ifreplaced,thevalvemustmeettherequirementsoflocalcodes,but
notlessthanacombinationtemperatureandpressure relief valve
certiedasindicatedintheaboveparagraph.
The valve must be marked with a maximum set pressure not to
exceedthemarkedhydrostaticworkingpressureofthewaterheater
(150psi=1,035kPa)andadischargecapacitynotlessthanthe
water heater
Btu/hr input rate as shown on the water heater’s
modelratingplate.
Forsafeoperationofthewaterheater,thereliefvalvemustnotbe
removedfromitsdesignatedopeningnorplugged.
Thetemperature-pressurereliefvalvemustbeinstalleddirectlyinto
thefittingofthewaterheaterdesignedforthereliefvalve.Position
thevalvedownwardandprovidetubingsothatanydischargewill
exitonlywithin6inches(15.2cm)above,oratanydistancebelow
the structural floor. Be certain that no contact is made with any
liveelectricalpart.Thedischargeopeningmustnotbeblocked
orreducedinsizeunderanycircumstances.Excessivelength,
over30feet(9.14m),oruseofmorethanfourelbowscancause
restriction and reduce the discharge capacity of the valve, see
Figures10.
Novalveorotherobstructionistobeplacedbetweentherelief
valveandthetank.Donotconnecttubingdirectlytodischarge
drainunlessa6”(15.2cm)airgapisprovided.Topreventbodily
injury, hazard to life, or property damage, the relief valve must
beallowedtodischargewaterinquantitiesshouldcircumstances
demand.Ifthedischargepipeisnotconnectedtoadrainorother
suitablemeans,thewaterflowmaycausepropertydamage.
TheDischargePipe:
•Shallnotbesmallerinsizethantheoutletpipesizeofthevalve,or
haveanyreducingcouplingsorotherrestrictions.
•Shallnotbepluggedorblocked.
•Shallbeofmateriallistedforhotwaterdistribution.
•Shallbeinstalledsoastoallowcompletedrainageofboththe
temperature-pressurereliefvalve,andthedischargepipe.
•Shallterminateatanadequatedrain.
•Shallnothaveanyvalvebetweenthereliefvalveandtank.