Owners manual

Instruction Manual
14
Alternative Hot-Key Control
Instead of using the keyboard leading hot-key sequence, [Ctrl] - [Ctrl],
the “Selection” button on the Host or Remote units can be used. These
commands can be used regardless if the “Mask Hotkey” feature is
enabled.
Command Sequence - Host Unit
Hot-Key Description
[press + hold Selection button for
2 sec] - [F3]
Sets the interval of inactivity in seconds
that the Host Unit will wait before
returning to Auto Mode
[press + hold Selection button for
2 sec] - [F6]
Change video Privacy Settings.
[press + hold Selection button for
2 sec] - [V] - 4 digit code
Set maximum video resolution for
both Remote/Host units.
Command Sequence - Remote Unit
Hot-Key Description
[press + hold Selection button for
2 sec] - [F11]
Enter Video Calibration mode.
[press + hold Selection button for
2 sec] - [V] - 4 digit code
Set maximum video resolution for
both Remote/Host units.
NOTE: Before entering Video Calibration mode, please make sure that
the Host and Remote Units are properly connected using Cat5/5e/6 UTP
cabling and the Remote Unit is in Remote mode (‘Remote’ LED flashing,
‘Local’ LED off).