Consult the following table to determine which pins to short in order to set a RAID
mode:
RAID mode Short pins
RAID 1 1-2, 5-6
RAID 0 3-4, 5-6
SPAN 1-2, 3-4, 5-6
JBOD/PM 5-6
Congure a RAID mode
Warning! When you set or change your RAID conguration, you will erase the data
or metadata on your existing drives. Save or back up any important data before you
proceed.
1. Set the RAID jumper switches to the conguration that corresponds to the mode
that you want to set.
2. Set J2 jumper to SET - GND.
3. Connect the adapter to the data and power connections on your SATA host device.
Refer to the documentation that came with your SATA host device for more
information about how to connect your adapter.
4. Make sure that the adapter is receiving power.
5. Disconnect the adapter from the power connection on your SATA host device.
6. Set the J2 jumper to SET - N.C.
7. Reconnect the adapter to the data and power connections on the your SATA host
device.
8. Navigate to Device Manager and make sure that the RAID change has taken eect.