A user-dened description for the controlled machine.
This menu allows you to congure a number of settings, including changing the
default password for admin (recommended). Read and consider the comments and
instructions on this menu before making any changes, as changing these features
could make the unit inaccessible through Web conguration (i.e. due to rewall
ltering). Note that any password changes you make will have to be entered in
duplicate to prevent the chance for error.
The Compatibility menu oers features that may oer enhanced functionality with
certain KVM and power products, such as StarTech.coms Remote Power Switch
(PCM8155HNA). These can be left at their default values if you are not connecting the
unit to a KVM or power management device.
The SNMP menu allows you to congure the SV1115IPEXT so it can be recognized and
managed using industry-standard Simple Network Management Protocol software.
The RADIUS server requires the IP address, the UDP port number (1812 - default or
1645) and the shared secret. The shared secret is used to encrypt communications
and corresponds to a shared password for the RADIUS server and the client machine.
Two additional servers may be dened for backup purposes. Each server will be
tried in order, using the indicated number of retries and timeout period, which are
congurable on the same page.