Quick Start Guide

Instruction Manual
6
Using the serial console command port
The media converter features a DB9 (RS232 serial) port, which enables console-based
management commands, for enhanced customization and control of the converter.
Media converter default settings:
Baud Rate: 38,400
Data bits: 8
Parity bits: none
Stop bits: 1
Handshaking: none
Emulation: VT-100
Default username/password: admin/admin (case sensitive)
1. If connected, disconnect the power adapter from the media converter’s DC power
input port.
2. Connect a straight-through DB9 RS232 cable (not provided) from the media
converter’s DB9 serial port to a serial console (for example, a laptop with a DB9 serial
port).
3. Run a terminal emulation application (for example, PuTTY).
4. Reconnect the power adapter that was disconnected in step #1.
Approximately three seconds after you power up the media converter, it will display a
login menu.
5. Login with the following details:
User Name: admin (case sensitive)
Password: admin (case sensitive)
6. Congure and control the media converter to suit your network requirements, using
the available menu options.