Instructions / Assembly

4
6. Fold the wires into the junction box and replace the cover.
7. Make sure all the screws are seated so there is no space between the cover and the junction box.
8. Run the electrical cable to the vehicle power system, supporting the cable as necessary and protecting
it from the sharp edges, heat and anything that could damage the cable.
9. Strip the outer cable covering as necessary. Make a solid electrical connection to the vehicle frame with
the ground green/white wire.
10. To determine if the vehicle electrical system is negative (-) or positive (+) ground, check the battery
marking of the terminal that is wired to the vehicle frame or motor block. For vehicles with a negative
ground, connect the negative (black) to the vehicle frame. For vehicles with a positive ground, connect the
positive (red) wire to the vehicle frame.
11. Attach one end of the 30amp fuse holder to the end of the remaining wire. Connect the other end of
the fuse holder to the ungrounded side of the power source. The battery terminal or the end of the battery
cable is recommended.
12. Check all connections to make sure they are correct. Install the 30 amp slow blow fuse in the fuse
holder.
OPERATION
To ensure ultimate performance, the pump must be setup according to INSTALLATION section of this
manual. On the initial start-up, it may be necessary to hold the nozzle open a few seconds to allow the
pump to prime:
1. Remove the nozzle from the pump and insert into the tank.
2. Turn the pump ON by lifting the switch lever.
3. Begin fuelling by squeezing the nozzle lever.
CAUTION: The pump motor is equipped with thermal overload protection. If overheated, it will
shut off without any damage to the windings. Be sure to turn off the pump power if this occurs. As
the motor cools, it will start without warning if the power is on.
MAINTENANCE
Disconnect power to the pump before servicing the pump.
To keep the pump running at its best, thoroughly ush pumps to be stored for long periods of time with
diesel fuel.
Remove and clean the strainer screen after every 20 hours of operation. Cleaning frequency depends
on the uids being pumped.
For your safety, service and maintenance should be performed regularly by a qualied technician.
Take motors needing service to an authorized repair shop to maintain “explosion proof” integrity.