Datasheet

Page 3/7
Safety data sheet
according to 1907/2006/EC, Article 31
Printing date 11.12.2019 Revision: 11.12.2019Version number 5.4
Trade name: Flux-Gel HX21
(Contd. of page 2)
50.0.2
See Section 13 for disposal information.
SECTION 7: Handling and storage
·
7.1 Precautions for safe handling
Ensure good ventilation/exhaustion at the workplace.
Prevent formation of aerosols.
·
Information about fire - and explosion protection:
Keep respiratory protective device available.
·
7.2 Conditions for safe storage, including any incompatibilities
·
Storage:
·
Requirements to be met by storerooms and receptacles:
No special requirements.
·
Information about storage in one common storage facility:
Not required.
·
Further information about storage conditions:
Keep container tightly sealed.
·
Storage class:
8 B
·
7.3 Specific end use(s)
No further relevant information available.
SECTION 8: Exposure controls/personal protection
·
Additional information about design of technical facilities:
No further data; see item 7.
·
8.1 Control parameters
·
Ingredients with limit values that require monitoring at the workplace:
CAS: 110-91-8 morpholine
WEL (Great Britain) Short-term value: 72 mg/m³, 20 ppm
Long-term value: 36 mg/m³, 10 ppm
Sk
IOELV (EU) Short-term value: 72 mg/m³, 20 ppm
Long-term value: 36 mg/m³, 10 ppm
·
Additional information:
The lists valid during the making were used as basis.
·
8.2 Exposure controls
·
Personal protective equipment:
·
General protective and hygienic measures:
Keep away from foodstuffs, beverages and feed.
Immediately remove all soiled and contaminated clothing
Wash hands before breaks and at the end of work.
Do not inhale gases / fumes / aerosols.
Avoid contact with the eyes.
Avoid contact with the eyes and skin.
·
Respiratory protection:
Not necessary if room is well-ventilated.
Use suitable respiratory protective device in case of insufficient ventilation.
·
Protection of hands:
_S
Protective gloves
Rubber gloves
Synthetic rubber gloves
To avoid skin problems reduce the wearing of gloves to the required minimum.
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.
Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the
chemical mixture.
Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation
(Contd. on page 4)