Problem
Possible Cause(s) Solution
Fan does not turn when electricity
is connected.
1. No electric power to heater.
2. Power switch is off.
3. Blades of fan in contact with heater
housing.
4. Fan blades bent.
5. Fan motor defective.
1. Check current at outlet. If voltage is
correct, inspect extension and power
cords for cuts, frays or breaks.
2. Press red power switch to ON.
3. Check housing for damage. Be sure
there are no dents in the housing
obstructing the fan.
4. Straighten all fan blades.
5. Replace motor assembly.
Heater will not re (ignite).
1. No spark at module.
2. Incorrect spark gap.
3. Corroded electrode.
1. Inspect module wire. Reattach or
tighten if loose. Inspect spark module.
Inspect all other electrical components.
2. Set plug gap to 0.16” (4 mm).
3. Clean electrode.
Heater stops running
by itself.
1. Temperature inside heater is too high,
causing thermal switch to shut down
operation.
2. Dust or debris accumulated
in heater.
1. If the heater input or output is
restricted, the inside temperature can
become too hot. Keep the areas in front
and behind heater clear of obstructions.
2. Clean inside of heater.