Operation Manual

18
77-122
90° Vertical Beam Accuracy
You will need at least 1,5 m
2
(16 ft
2
) of floor space and possibly an assistant for this check.
1. Place the laser unit on a level floor, and
turn on all beams.
2. Measure exactly 0,91 m (3 ft) out from
the center of the laser unit along the front
vertical laser beam. Mark this point P
1
.
3. Measure exactly 1,22 m (4 ft) out the
center of the instrument along either of
the 90° vertical reference beams, and
mark this point P
2
.
4. Measure from point A to point B; this
distance D
1
should equal 1,522 m ± 0,3 mm
(5 ft ± 1/64 in). If not, the unit must be
returned to your Stanley Distributor.
5. Repeat steps 1 through 4 to check the
other beams.
P
1
0,91 m (3 ft)
P
1
1,22 m (4 ft)
P
2
P
1
P
2
D
1