User Manual
Installation Instructions for Wi-Q™ Technology 45HQ Mortise Locks
BEST ACCESS SYSTEMS
a Product Group of Stanley Security Solutions, Inc
11
Installation Instructions for Wi-Q™ Technology 45HQ Mortise Locks
Completing the installation
19 Install strike box and strike plate
1 Insert the strike box into the mortise in the door jamb.
Place the strike plate over the strike box and secure the
strike with the screws provided.
2 Check the position of the auxiliary bolt against the
strike plate.
Caution: The auxiliary bolt must make contact with the
strike plate. The auxiliary bolt deadlocks the latchbolt
and prevents someone from forcing the latch open
when the door is closed. If the incorrect strike is
installed, a lock-in can occur.
Note: The recommended gap between the door and
jamb is 1/8″.
Figure 19a Installing the strike box and strike plate
Strike
box with
magnet
Strike
plate
Door jamb
Make sure to
position the
magnet at
the top.
Figure 19b Positioning the strike
Auxiliary bolt
Strike plate