User Manual
211
Status Flags in the FLAGS Column
The following is a list of the bits in the FLAGS column and their corresponding
Portal Gateway status flags and definitions (Figure 157, item 12).
Note The typical Wi-Q and Omnilock device status code is 00030043. This is the example
used in the chart below.
Bit Portal Gateway Status Flag Definition
Right
END
3
Bit 0
CONTROLLER_IS_ASSOCIATED
Set when the Controller is first associated with
the Portal.
Bit 1
CONTROLLER_IS_VALID
Set during association, after the Portal
receives a beacon from the Controller.
Bit 2 CONTROLLER_CONFIG_REQUIRED
Set during association, cleared by Portal
Communication Service after Controller
configuration.
Bit 3 CONTROLLER_ASSOC_PENDING_LIF
Set during association to indicate that Portal
requires LIF (Lock Information Frame) data.
4
Bit 4 CONTROLLER_BEGIN_TRANSMISSION
Set when Portal first transmits data to the
Controller.
Bit 5 CONTROLLER_DEEP_RESET_PENDING
Portal must disassociate Controller when it
receives the next beacon.
Bit 6
CONTROLLER_VALID_INTERVALS
Set when Controller interval assignment has
been received from the PC Communication
Service.
Bit 7 NOT USED
0
Bit 8
CONTROLLER_RETRY_LIMIT_
EXCEEDED
Set when the retry limit on any command has
been hit; used to limit downloads to firmware
only.
Bit 9 NOT USED
Bit 10 NOT USED
Bit 11 NOT USED
0
Bit 12 NOT USED
Bit 13
CONTROLLER_PREFERRED_PG_
ENABLED
Set when Controller is locked to the Portal.
Bit 14
CONTROLLER_FIRMWARE_PENDING_
DN
Set when the firmware commit has been sent
to indicate that the disassociation is pending.
Bit 15 CONTROLLER_FIRMWARE_PENDING
Set when firmware update is scheduled for
the Controller, cleared when firmware commit
is sent.
3
Bit 16
CONTROLLER_REPORT_TIME
_UPDATED
Set during association and when report time
is updated
Bit 17
CONTROLLER_LIF_IS_VALID Set when a LIF beacon is received
Left
END
Bit 18-31 NOT USED