User Manual
161
Programmer Override at Keypad Reader
When an AMS User is assigned a Programmer Type, that user can present their
credential and perform the following.
Note PC refers to Programmer Credential.
Deep Reset
At times it may be necessary to perform a Deep Reset on a Controller. For exam-
ple, when you install a dial up gateway modem, you must temporarily clear reader
data. If the reset button inside the Controller housing is not accessible, you can
use the Programmer Override to perform a Deep Reset. You can also perform a
deep reset from within Configurator.
To Perform a Deep Reset from within Configurator
1 In the Configurator’s Readers Tab, navigate to the desired reader using the
Segment Tree.
2 In the list on the right, right-click on the reader and select Deep Reset from the
drop-down list. Reader data will be cleared.
3 To bring the reader back into the software, you must perform a standard sign
on procedure.
Note If the reader does not respond and perform the Deep Reset within five minutes, the
action will be aborted.
Item
WDC WAC Omnilock
Function
Programmer
Code
PC# PC PC Momentary Unlock.
Soft Reset PC# + 1# PC + 1111 PC + 1 Soft resets device.
Motor Reset PC# + 2# PC + 2222 PC + 2 Resets the motor drive.
Comm.
Processor
Reset
PC# + 7# PC + 7777 PC + 7 Resets the communication
processor.
Motor Test PC# + 8# PC + 8888 PC + 8 Runs motor test.
Deep Reset MC# + 9# MC + 9999 MC + 9 Deep resets device.