2.4.0 CP190i Connection Table
Power Data Cable
Pin Wire Color Description Connection Example Additional Comments
1 Black Battery Ground Connect to Battery Ground
2 Red Battery Positive Connect to Battery Positive
3 Green NMEA Common Common (ground) for NMEA devices**
4 Blue Port1 Input Connect to Output of NMEA devices** Default is NMEA 0183
5 Brown Port1 Output Connect to Input of NMEA devices** Default is NMEA 0183 with GGA, GLL, RMC,
DBT, DPT, MTW, VHW and XTE sentences
6 Grey Port2 Input Connect to FF525 Default is Fish Finder
7 White Port2 Output Connect to FF525 Default is Fish Finder
8 Yellow Port3 Output Connect to Input of NMEA devices** Default is NMEA 0183 with APA, APB, BOD,
GGA, GLL, RMC and BOD sentences*
NOTE* AUTOPILOT CONNECTION
Care must be taken when connecting the GPS Chart Plotter to an Autopilot. Normally Port3 (Yellow
wire) will be used to connect to an Autopilot input, however older autopilots may not be able to read
the sentences due to the talker ID that is being used (II Integrated Instrument). If the Autopilot
connections are made to Port3 (Yellow wire) and the Autopilot is not reading the sentences, change
the connections to Port1 (Brown wire) and change the sentences to APA, APB, BOD, GGA, GLL,
RMC and XTE.