User Manual
9
programming mode so the user can
undertake this themselves
To delete a Card and PIN user just delete
the card
2 User ID #
To add a card user in card mode (3 0 # )
To Add and Delete a card user
The operating is the same as adding and deleting a card
user in 3 2 #
To delete All users
To delete ALL users. Note that this is a
dangerous option so use with care
2 0000 #
To unlock the door
For a PIN user
Enter the PIN then press #
For a card User
Read card
For a card and PIN user
Read card then enter PIN #
11.2 Door Settings
Relay Output Delay Time
To set door relay strike time * Master code # 4 0~99 # *
0-99 is to set the door relay time 0-99 seconds
Door Open Detection
Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in
magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside
buzzer will beep automatically to remind people to close the door and continue for 1 minute before
switching off automatically.
Door Forced Open warning. When used with an optional magnetic contact or built-in magnetic contact
of the lock, if the door is forced open, or if the door is opened after 20 seconds ,the inside buzzer and
alarm output will both operate. The Alarm Output time is adjustable between 0-3 minutes with the
default being 1 minute.
To disable door open detection. (Factory
default)
6 0 #
To enable door open detection 6 1 #
Alarm output time
To set the alarm output time (0-3 minutes)
Factory default is 1 minute
5 0~3 #