7
mode
Open the door - Bright - Di
Alarm Bright - - Alarm
11. Detailed Programming Guide
11.1 User Settings
To enter the programming mode
* Master code #
999999 is the default factory master code
To exit from the programming mode *
Note that to undertake the following programming the master user must be logged in
To change the master code 0 New code # New code #
The master code can be 6 to 8 digits long
Setting the working mode:
Set valid card only users
Set valid card and PIN users
Set valid card or PIN users
3 0 # Entry is by card only
3 1 # Entry is by card and PIN together
3 2 # Entry is by either card or PIN (default)
To add a user in either card or PIN mode, i.e. in the 3 2 # mode. (Default setting)
To add a Pin user
1 User ID number # PIN #
The ID number is any number between 1 & 2000. The
PIN is any four digits between 0000 & 9999 with the
exception of 1234 which is reserved. Users can be added
continuously without exiting programming mode as
follows:
1 User ID no 1 # PIN # User ID no 2 # PIN #
To delete a PIN user
2 User ID number #
Users can be deleted continuously without exiting
programming mode
To change the PIN of a PIN user
(This step must be done out of
programming mode)
* ID number # Old PIN # New PIN # New PIN #
To add a card user (Method 1)
This is the fastest way to enter cards,
user ID number auto generation.
1 Read card #
Cards can be added continuously without exiting
programming mode