Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN numbers
in a 10 minute period either the keypad will lockout for 10 minutes or both the alarm and the inside
buzzer will operate for 10 minutes, depending on the option selected below.
Normal status: No keypad lockout or
alarm (factory default)
7 0 # (Factory default setting)
Keypad Lockout 7 1 #
Alarm and inside buzzer operate 7 2 #
To remove the alarm
To reset the Door Forced Open warning Read valid card or Master Code #
To reset the Door Open Too Long warning
Close the door or Read valid card or Master Code #
12.The unit operating as a Wiegand Output Reader
In this mode the unit supports a Wiegand 26 bit output so the Wiegand data lines can be
connected to any controller which supports a Wiegand 26 bit input.