Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm×60mm,Special for keypad Rubber plug 2 Φ6mm×30 mm, used for fixing Self tapping screws 2 Φ4mm×28 mm, used for fixing Star screws 1 Φ3mm×6mm, used for fixing Please ensure that all the above contents are correct. If any are missing please notify the supplier of the unit.
. Quick Reference Programming Guide To enter the programming mode * Master code # 999999 is the default factory master code To exit from the programming mode * Note that to undertake the following programming the master user must be logged in To change the master code 0 New code # New code # The master code can be 6 to 8 digits To add a PIN user. 1 User ID number # PIN # The ID number is any number between 1 & 2000.
warehouses, laboratories, banks and prisons. 4.
Fix the back cover firmly on the wall with 2 Self tapping screws Thread the cable through the cable hole Attach the keypad to the back cover.
7.
special power supply diagram: 8. To Reset to Factory Default a. Disconnect power from the unit b. Press and hold # key whilst powering the unit back up c. On hearing two “Di” release # key, system is now back factory settings Please note only installer data is restored, user data will not be affected 9. Anti Tamper Alarm The unit uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad is removed from the cover then the tamper alarm will operate. 10.
mode Open the door Alarm - Bright - Di Bright - - Alarm 11. Detailed Programming Guide * 11.
To add a card user (Method 2) 1 This is the alternative way to enter cards User can be added continuously without exiting using User ID Allocation. In this method a ID number # Read card # programming mode User ID is allocated to a card. Only one user ID can be allocated to a single card.
programming mode so the user can undertake this themselves To delete a Card and PIN user just delete 2 User ID # the card To add a card user in card mode (3 0 To Add and Delete a card user #) The operating is the same as adding and deleting a card user in 3 2 # To delete All users To delete ALL users.
Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN numbers in a 10 minute period either the keypad will lockout for 10 minutes or both the alarm and the inside buzzer will operate for 10 minutes, depending on the option selected below.