User manual

Symptom Remedy
The unit does not work Check the mains connection and the main fuse.
No response to the DMX controller 1. Check the DMX connectors and cables for proper connection.
2. Check the address settings and the DMX polarity.
3. Try using another DMX controller.
4. Check to see if the DMX cables run near or alongside to high voltage cables
that may cause damage or interference to DMX interface circuits.
No fog output 1. Check the uid level in the fog container.
2. Switch the device o and check the hose that leads into the uid container
for ow.
3. Check if the protective circuit has been reset after tripping, see
Ä
‘Dry-run
protection’ on page 24.
If the procedures recommended above do not succeed, please contact our Service Center. You
can nd the contact information at www.thomann.de.
Troubleshooting
M-Fog 1000, M-Fog 1500, M-Fog 2500
33