User manual

Technical data
8
206676 / 614860300010
2015-02-10·BA00·III·en·04
Portable Lamp
Series 6148
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Luminous
characteristics
Lamps main light, LED: 3 W
secondary light, LED: 0.5 W
Light intensity 24,000 cd
CCT 6500 K
Light distribution acc. to DIN 14642
Functions continuous light or flashing light of the main light, continuous light of the
secondary light, function of the main light continuously dimmable
Emergency light
duration
Deep discharge
protection
At a residual capacity of the battery of < 10 %, the main light is automatically
switched to the secondary light.
Test function
Lamp control When the main light is defective, the light is switched automatically to the
secondary light
Battery capacity Determination of the current battery capacity
Mechanical data
Degree of protection IP66 (IEC/EN 60589)
Enclosure material Polyamide, impact-strength
Head tilting toward the front: 100°, toward the back: 90°
Pushbutton main light ON - secondary light ON - main light FLASHING OFF
Charge state display The LEDs indicate the available capacity for approx. 5 seconds
Ambient conditions
Ambient temperature -20 ... +50 °C
Storage temperature -20 ... +50 °C
Charging unit
Version charging unit 6148/0000 (for explosion-protected portable lamps)
supply voltage: 110 ... 240 V AC, 50 / 60 Hz and 12 ... 30 V DC
with emergency lighting function and automatic break device for motor vehicle
operation
with power supply cable for 110 ... 240 V AC, 50 / 60 Hz
Optionally, a charging cable for motor vehicle operation for 12 ... 30 V DC is
available.
Charging current
Charging time approx. 11 h
Technical Data
main light: continuous duty:
flashing mode:
continuously on, typical 7 h
flashing up to 18 h
secondary light: continuous duty: continuously on, typical 32 h
at room temperature:
charging process stand by
12 V DC
24 V DC
110 V AC
240 V AC
max. 170 mA
max. 120 mA
max. 90 mA
max. 60 mA
power consumption < 1 W