Room thermostat (2)
The room-thermostat control (2) allows for an infinitely variable temperature
adjustment.
Setting: for maximum temperature turn the control clockwise,
for minimum temperature, turn the control anti-clockwise.
Turn the thermostat control (2) clockwise as far as the stop. If the desired
room temperature has been reached, turn the thermostat control (2) anti-
clockwise until the appliance switches off. If the room temperature drops,
then MAX switches on again automatically.
Frost-protection circuit
*
Set the room-thermostat control (2) to
*
.
To prevent the room temperature from falling below approx. +5°C, set the
rotary control (1) to position I or II (depending on the size of room, Position II
for larger rooms) and the room-temperature control (2) to
*
. The appliance
switches on automatically at approx. +5°C and off again at approx. +7°C. In
this way frost damages can be avoided.
Protection against over-heating
MAX is fitted with an over-temperature safety device which switches off
the appliance in the case of a technical fault or improper use. Should this
occur, pull the mains cable (7) out of the supply socket and remedy the fault
or correct the method of use. The appliance can be put back into use when
it has cooled down and has been disconnected from the mains supply for a
short time.
Note: make quite sure that there is always sufficient space between
the appliance and the wall or other large objects. The air flow must
not be impeded by objects of any kind.
Specifications
Rated voltage 230 volt / 50 Hz
Rated power 2000 watt (Position II)
Measurements 290 x 368 x 270 mm
(width x height x depth)
Weight approx. 2.5 kg
Heating settings 0 - - 1000 - 2000 watt
Thermostat infinitely variable
Automatic frost protection fitted
Over-heating protection fitted
Double insulation yes
Sound level less than 40dB(A)
Complies with EU regulations GS/CE/WEE/RoHS