User manual

Alarm muting
If an alarm is triggered, for instance, by burnt food or heavy cigarette smoke, the smoke alarm device
can be muted for approx. 10 min. by pressing the test button. Meanwhile the red LED flashes every 8 sec.
Important: You should only use this function if the harmless cause of this smoke emission is
definitely identified!
Thoroughly ventilate the affected room. The alarm muting is automatically deactivated after approx. 10 min.
If the contamination in the air through smoke particles is still too high then, the alarm signal sounds again.
You can use and activate the mute function several times.
Note: The mute function does not function in case of extreme smoke emission.
Exchanging / replacing the alarm system
The power supply of the stabo smoke alarm device is provided through a permanently installed, non-
exchangeable lithium battery having a lifetime of approx. 10 years under normal operating conditions
(high humidity and very high/low temperatures can reduce the batterys life time). If the battery capacity
becomes weak (or the device is defective), a clearly audible beep sounds every 40 seconds (warning
duration: 30 days at least). In this case, remove the smoke alarm device and install a new one.
Disposal instruction
Electronic devices and used up batteries are not to be thrown into the domestic waste!
Hand in the device at your municipal waste disposal company or a collecting point specialized in electronic
scrap.
Technical data
Operating voltage Permanently installed 3 V lithium battery (CR123A)
Operating current (stand-by) < 8uA
Operating current (alarm) < 50 mA
Acoustic alarm indication Piezosiren 85 dB (A) /3 m
Optical alarm indication rapidly flashing LED
Test function Test button with LED display
Temperature range approx. 4°C to 40°C
Relative humidity 10 % - 90 %
Dimensions
Ø 100 mm, height 35 mm
Weight 106 g
Disclaimer
stabo shall not be liable for loss and/or damage of any kind (including individual or consequential damage)
resulting from the fact that the signal of the smoke alarm device was not activated in the presence of
smoke or fire.
Furthermore, stabo shall also not be held liable for the consequences of false or deceptive alarms: Costs
resulting, for instance, from operations of the fire brigades or key services are not covered.