User manual

Mounting and commissioning
If you want to lock the smoke alarm device on the mounting afterwards,
remove the fixing pin now (e.g. by means of a screw driver).
Mark the position for the drilling holes at the mounting position by using
the mounting as a drilling jig.
Drill the appropriate two holes for the fixing screws (please use the
enclosed dowels for an installation on a masonry or gypsum subsurface)
and screw down the mounting.
Turn the smoke alarm device clockwise on the mounting, until it locks
in.
Important: The smoke alarm device has to be activated now!
Press the test button for about 5 sec. until an alarm tone sounds. If the
LED flashes slowly (approx. every 40 sec.), the smoke alarm device
is operable.
If required you can now additionally lock the smoke alarm device on the mounting
by sticking the fixing pin into the small opening.
Function test
After having installed the smoke alarm device, you should necessarily perform a function test!
Do not expose your ears directly to the alarm signal, but hold the device at arms length. Press the test
button (large round button in the middle) for approx. 5 sec. until the alarm signal sounds and the LED
flashes rapidly.
Test your smoke alarm device regularly (at least once a year) as well as after a long absence (holiday
trip or the like).
LED indicators und alarm tones
Operating status LED Acoustic signal
Readiness for operation slowly flashing (every 40 sec.) -
Test function rapidly flashing loud beeps in rapid sequence
Alarm triggering rapidly flashing loud beeps in rapid sequence
Alarm muting flashes every 8 sec. -
Battery-low-warning slowly flashing (every 40 sec.) beep every 40 sec.
Malfunction indicator slowly flashing (every 40 sec.) beep every 40 sec.